直近一年間の累計
アクセス数 : ?
ダウンロード数 : ?
ID 116024
タイトル別表記
Fogarty catheter for OLV of a neonate
著者
Sasaki, Hideto Tokushima University
Sogabe, Yohei Tokushima University
Hirota, Kentaro University Hospital
Honda, Yasuto Tokushima University
キーワード
neonatal and infantile one-lung ventilation
slip joint section
Fogarty catheter
資料タイプ
学術雑誌論文
抄録
Here, we report two cases involving a neonate and child in which a slip joint section was used to thread a Fogarty catheter into the endotracheal tube for one-lung ventilation (OLV). Both the neonate and infant required OLV, and were placed under general anesthesia. A Fogarty catheter was used for OLV. The Fogarty catheter was passed into the intraluminal side of the endotracheal tube through a slip joint section. OLV was maintained successfully without severe air leakage or Fogarty catheter displacement. The neonate had been intubated pre-operatively with a 3.5-mm inner diameter endotracheal tube, and we used that tube. These cases indicate that the technique can be applied to pre-operatively intubated patients and does not require surgeons to exchange endotracheal tubes. Use of the slip joint section technique facilitates Fogarty catheter fixation without additional dead space.
掲載誌名
The Journal of Medical Investigation
ISSN
13496867
13431420
cat書誌ID
AA11166929
出版者
Tokushima University Faculty of Medicine
68
1-2
開始ページ
209
終了ページ
212
並び順
209
発行日
2021-02
出版社版DOI
出版社版URL
フルテキストファイル
言語
eng
著者版フラグ
出版社版
部局
病院
医学系