ID | 113411 |
タイトル別表記 | Infection risk in hemodialysis patient
|
著者 |
Honjo, Airi
Tokushima University
Tsunedomi, Akari
Tokushima University
Hatayama, Sho
Tokushima University
Sato, Yuri
Tokushima University
Kido, Junko
Tokushima University
Nishisaka, Risa
Tokushima University
Yoshimoto, Ayumi
Tokushima University
Yamashita, Tomoko
Tokushima University
Amano, Sachie
Tokushima University
Maetani-Yasui, Miki
Tokushima University|Osaka Prefecture University
Iba, Hitomi
Tokushima University|Nagasaki International University
Harada, Yumi
Tokushima University
|
キーワード | Bacterial infection
Bacterial contamination
Hemodialysis device
Methicillin Resistant Staphylococcus
|
資料タイプ |
学術雑誌論文
|
抄録 | Chronic care patients undergoing hemodialysis for treatment of end-stage renal failure experience higher rates of bloodstream-associated infection due to the patients' compromised immune system and management of the bloodstream through catheters. Staphylococcus species are a common cause of hemodialysis catheter-related bloodstream infections. We investigated environmental bacterial contamination of dialysis wards and contamination of hemodialysis devices to determine the source of bacteria for these infections. All bacterial samples were collected by the swab method and the agarose stamp method. And which bacterium were identified by BBL CRYSTAL Kit or 16s rRNA sequences. In our data, bacterial cell number of hemodialysis device was lower than environment of patient surrounds. But Staphylococcus spp. were found predominantly on the hemodialysis device (46.8%), especially on areas frequently touched by healthcare-workers (such as Touch screen). Among Staphylococcus spp., Staphylococcus epidermidis was most frequently observed (42.1% of Staphylococcus spp.), and more surprising, 48.2% of the Staphylococcus spp. indicated high resistance for methicillin. Our finding suggests that hemodialysis device highly contaminated with bloodstream infection associated bacteria. This study can be used as a source to assess the risk of contamination-related infection and to develop the cleaning system for the better prevention for bloodstream infections in patients with hemodialysis.
|
掲載誌名 |
The Journal of Medical Investigation
|
ISSN | 13496867
13431420
|
cat書誌ID | AA12022913
AA11166929
|
出版者 | Tokushima University Faculty of Medicine
|
巻 | 66
|
号 | 1-2
|
開始ページ | 148
|
終了ページ | 152
|
並び順 | 148
|
発行日 | 2019-02
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
医学系
生物資源系
理工学系
|