ID | 118790 |
タイトル別表記 | Early urinary catheter removal in stroke
|
著者 |
Ueno, Yoshiteru
Tokushima University
Tomida, Ryotaro
Tokushima University
|
キーワード | Urinary catheter
voiding function
physical function
stroke
|
資料タイプ |
学術雑誌論文
|
抄録 | Objective : The aim of the present study was to identify factors related to the success of trial without catheter (TWOC) in patients with stroke and to examine the effect of the timing of urinary catheter removal on the course of stroke. Methods : Patients who were admitted to the Stroke Care Unit of our institution between March 2018 and October 2021 were included. To identify factors related to success of TWOC, a multivariate analysis was performed on the patient’s condition at admission and catheter indwelling time. The patients were divided into two groups by the timing of catheter removal, and we assessed the relationship between the timing of catheter removal successful TWOC and recovery of physical function. Results : A total of 118 patients were included. The presence of comorbidities and scores of severity and function at admission were not predictors of successful voiding. The time to achieve voiding sussess was significantly shorter in the early catheter removal group than in the later group (p < 0.005). Interestingly, the early group also showed better improvements in physical function. Conclusion : Early removal of catheters may lead to early recovery of bladder function, improvement of physical function, and lower risk of complications in patients with stroke.
|
掲載誌名 |
The Journal of Medical Investigation
|
ISSN | 13496867
13431420
|
cat書誌ID | AA11166929
|
出版者 | Tokushima University Faculty of Medicine
|
巻 | 70
|
号 | 3-4
|
開始ページ | 436
|
終了ページ | 442
|
並び順 | 436
|
発行日 | 2023-08
|
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
病院
医学系
|