直近一年間の累計
アクセス数 : ?
ダウンロード数 : ?
ID 83831
著者
Lan, Hai Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School|Department of Radiology, Inner Mongolia International Mongolian Hospital
西谷, 弘 Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
西原, 貞光 Department of Biomedical Information Sciences, Institute of Health Biosciences, the University of Tokushima Graduate School KAKEN研究者をさがす
上野, 淳二 Department of Biomedical Information Sciences, Institute of Health Biosciences, the University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
髙尾, 正一郎 Department of Biomedical Information Sciences, Institute of Health Biosciences, the University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
岩本, 誠司 Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School KAKEN研究者をさがす
川中, 崇 Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
Mahmut, Mawlan Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School
Qingge, Si Department of Radiology, Inner Mongolia International Mongolian Hospital
キーワード
pulmonary emphysema
MDCT
MinIP
資料タイプ
学術雑誌論文
抄録
Abstract : Purpose : The purpose of this study was to evaluate the usefulness of thick slabminimum intensity projection (MinIP) as a follow-up method in patients with pulmonaryemphysema. This method was used to determine the presence or absence of changes overtime in the lung field based on multi-detector-row CT (MDCT) data. Methods : Among patientsdiagnosed with pulmonary emphysema who underwent 16-MDCT (slice thickness,1 mm) twice at an interval of 6 months or more, 12 patients without changes in the lungfield and 14 with clear changes in the lung field were selected as subjects. An image interpretationexperiment was performed by five image interpreters. Pulmonary emphysemawas followed up using two types of thick slab MinIP (thick slab MinIP 1 and 2) andmulti-planar reformation (MPR), and the results of image interpretation were evaluatedby receiver operating characteristic (ROC) analysis. In addition, the time required forimage interpretation was compared among the three follow-up methods. Results : Thearea under the ROC curve (Az) was 0.794 for thick slab MinIP 1, 0.778 for the thick slabMinIP 2, and 0.759 for MPR, showing no significant differences among the three methods.Individual differences in each item were significantly more marked for MPR thanfor thick slab MinIP. The time required for image interpretation was around 18 secondsfor thick slab MinIP 1, 11 seconds for thick slab MinIP 2, and approximately 127 secondsfor MPR, showing significant differences among the three methods. Conclusion : Therewere no significant differences in the results of image interpretation regarding the presenceor absence of changes in the lung fields between thick slab MinIP and MPR. However,thick slab MinIP showed a shorter image interpretation time and smaller individualdifferences in the results among image interpreters than MPR, suggesting the usefulnessof this method for determining the presence or absence of changes with time in the lungfields of patients with pulmonary emphysema.
掲載誌名
The journal of medical investigation : JMI
ISSN
13431420
cat書誌ID
AA11166929
58
3-4
開始ページ
175
終了ページ
179
並び順
175
発行日
2011
備考
The journal of medical investigation : http://medical.med.tokushima-u.ac.jp/jmi/index.html
EDB ID
出版社版DOI
出版社版URL
フルテキストファイル
言語
eng
部局
医学系
病院