ID | 83831 |
著者 |
Lan, Hai
Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School|Department of Radiology, Inner Mongolia International Mongolian Hospital
西谷, 弘
Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
西原, 貞光
Department of Biomedical Information Sciences, Institute of Health Biosciences, the University of Tokushima Graduate School
KAKEN研究者をさがす
上野, 淳二
Department of Biomedical Information Sciences, Institute of Health Biosciences, the University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
髙尾, 正一郎
Department of Biomedical Information Sciences, Institute of Health Biosciences, the University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
岩本, 誠司
Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School
KAKEN研究者をさがす
川中, 崇
Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
Mahmut, Mawlan
Department of Radiology, Institute of Health Biosciences, the University of Tokushima Graduate School
Qingge, Si
Department of Radiology, Inner Mongolia International Mongolian Hospital
|
キーワード | pulmonary emphysema
MDCT
MinIP
|
資料タイプ |
学術雑誌論文
|
抄録 | Abstract : Purpose : The purpose of this study was to evaluate the usefulness of thick slabminimum intensity projection (MinIP) as a follow-up method in patients with pulmonaryemphysema. This method was used to determine the presence or absence of changes overtime in the lung field based on multi-detector-row CT (MDCT) data. Methods : Among patientsdiagnosed with pulmonary emphysema who underwent 16-MDCT (slice thickness,1 mm) twice at an interval of 6 months or more, 12 patients without changes in the lungfield and 14 with clear changes in the lung field were selected as subjects. An image interpretationexperiment was performed by five image interpreters. Pulmonary emphysemawas followed up using two types of thick slab MinIP (thick slab MinIP 1 and 2) andmulti-planar reformation (MPR), and the results of image interpretation were evaluatedby receiver operating characteristic (ROC) analysis. In addition, the time required forimage interpretation was compared among the three follow-up methods. Results : Thearea under the ROC curve (Az) was 0.794 for thick slab MinIP 1, 0.778 for the thick slabMinIP 2, and 0.759 for MPR, showing no significant differences among the three methods.Individual differences in each item were significantly more marked for MPR thanfor thick slab MinIP. The time required for image interpretation was around 18 secondsfor thick slab MinIP 1, 11 seconds for thick slab MinIP 2, and approximately 127 secondsfor MPR, showing significant differences among the three methods. Conclusion : Therewere no significant differences in the results of image interpretation regarding the presenceor absence of changes in the lung fields between thick slab MinIP and MPR. However,thick slab MinIP showed a shorter image interpretation time and smaller individualdifferences in the results among image interpreters than MPR, suggesting the usefulnessof this method for determining the presence or absence of changes with time in the lungfields of patients with pulmonary emphysema.
|
掲載誌名 |
The journal of medical investigation : JMI
|
ISSN | 13431420
|
cat書誌ID | AA11166929
|
巻 | 58
|
号 | 3-4
|
開始ページ | 175
|
終了ページ | 179
|
並び順 | 175
|
発行日 | 2011
|
備考 | The journal of medical investigation : http://medical.med.tokushima-u.ac.jp/jmi/index.html
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
部局 |
医学系
病院
|