ID | 114389 |
Author |
Liu, Renwei
Xi’an Jiaotong University|Tokushima University
Rong, Kai
Xi’an Jiaotong University
Wang, Zhenzhen
Tokushima University|Xi’an Jiaotong University
Cui, Minchao
Tokushima University|Northwestern Polytechnical University
Deguchi, Yoshihiro
Tokushima University|Xi’an Jiaotong University
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Tanaka, Seiya
Tokushima University
Yan, Junjie
Tokushima University|Xi’an Jiaotong University
Liu, Jiping
Xi’an Jiaotong University
|
Keywords | steel elemental analysis
sample temperature effect
SP-LIBS
collinear long-short DP-LIBS
|
Content Type |
Journal Article
|
Description | Laser induced breakdown spectroscopy (LIBS) has been investigated as a potential multi-element quantitative analysis tool for the quality control of on-line steel production. This research investigated influence of sample temperature on steel sample measurement using collinear long-short dual-pulse LIBS (long-short DP-LIBS) and single-pulse LIBS (SP-LIBS). The standard steel sample has been uniformly heated in a muffle furnace from 20°C to 700°C. The experimental results show that sample temperature has significantly effect on measurement result using SP-LIBS. However, long-short DP-LIBS can effectively reduce the sample temperature effect on measurement result. The detection characteristics of long-short DP-LIBS and SP-LIBS were compared using the intensity ratio of I Mn 404.136 nm/I Fe 400.524 nm and I Fe 402.187 nm/I Fe 400.524 nm under different delay time and different sample temperature conditions. The signal intensity and plasma temperature can be maintained higher and more stable for a period of time and at different sample temperature by long-short DP-LIBS with smaller error bar compared with that of SP-LIBS, which indicated long-short DP-LIBS has better measurement repeatability than SP-LIBS. The plasma temperature correction method was applied to compare the detection features of long-short DP-LIBS and SP-LIBS. The signal stability of long-short DP-LIBS measurement was improved significantly at different sample temperature with plasma temperature correction. These results demonstrated that the effect of sample temperature can be reduced using long-short DP-LIBS method to improve the on-line detection capability for steel measurement in
complex environment. |
Journal Title |
ISIJ International
|
ISSN | 09151559
13475460
|
NCID | AA10680712
|
Publisher | The Iron and Steel Institute of Japan
|
Volume | 60
|
Issue | 8
|
Start Page | 1724
|
End Page | 1731
|
Published Date | 2020-02-28
|
Rights | © 2020 The Iron and Steel Institute of Japan
|
EDB ID | |
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
Publisher
|
departments |
Science and Technology
|