Title Alternative
Detection Chip for Malaria
Author
Yatsushiro, Shouki National Institute of Advanced Industrial Science and Technology
Yamamura, Shohei National Institute of Advanced Industrial Science and Technology
Yamaguchi, Yuka National Institute of Advanced Industrial Science and Technology Tokushima University Educator and Researcher Directory
Tamiya, Eiichi Osaka University
Horii, Toshihiro Osaka University
Baba, Yoshinobu National Institute of Advanced Industrial Science and Technology|Nagoya University
Kataoka, Masatoshi National Institute of Advanced Industrial Science and Technology
Content Type
Journal Article
Description
Background: Malaria is one of the major human infectious diseases in many endemic countries. For prevention of the spread of malaria, it is necessary to develop an early, sensitive, accurate and conventional diagnosis system.
Methods and Findings: A cell microarray chip was used to detect for malaria-infected erythrocytes. The chip, with 20,944 microchambers (105 µm width and 50 µm depth), was made from polystyrene, and the formation of monolayers of erythrocytes in the microchambers was observed. Cultured Plasmodium falciparum strain 3D7 was used to examine the potential of the cell microarray chip for malaria diagnosis. An erythrocyte suspension in a nuclear staining dye, SYTO 59, was dispersed on the chip surface, followed by 10 min standing to allow the erythrocytes to settle down into the microchambers. About 130 erythrocytes were accommodated in each microchamber, there being over 2,700,000 erythrocytes in total on a chip. A microarray scanner was employed to detect any fluorescence-positive erythrocytes within 5 min, and 0.0001% parasitemia could be detected. To examine the contamination by leukocytes of purified erythrocytes from human blood, 20 µl of whole blood was mixed with 10 ml of RPMI 1640, and the mixture was passed through a leukocyte isolation filter. The eluted portion was centrifuged at 1,000×g for 2 min, and the pellet was dispersed in 1.0 ml of medium. SYTO 59 was added to the erythrocyte suspension, followed by analysis on a cell microarray chip. Similar accommodation of cells in the microchambers was observed. The number of contaminating leukocytes was less than 1 on a cell microarray chip.
Conclusion: The potential of the cell microarray chip for the detection of malaria-infected erythrocytes was shown, it offering 10–100 times higher sensitivity than that of conventional light microscopy and easy operation in 15 min with purified erythrocytes.
Journal Title
PLOS ONE
ISSN
19326203
Publisher
PLOS
Volume
5
Issue
10
Start Page
e13179
Published Date
2010-10-13
Rights
© 2010 Yatsushiro et al.This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
EDB ID
DOI (Published Version)
URL ( Publisher's Version )
FullText File
language
eng
TextVersion
Publisher
departments
AWA Support Center
Institute of Advanced Medical Sciences