ID | 116571 |
Title Alternative | Failure of Hem-o-lok clips
|
Author |
Yanagi, Masato
Nippon Medical School
Hamasaki, Tsutomu
Nippon Medical School
Shimizu, Hiroyuki
Hasegawa Hospital
Kimata, Ryoji
Nippon Medical School
Takeda, Hayato
Nippon Medical School
Akatsuka, Jun
Nippon Medical School
Endo, Yuki
Nippon Medical School
Hayashi, Tatsuro
Nippon Medical School
Kondo, Yukihiro
Nippon Medical School
|
Keywords | Hem-o-lok clip
laparoscopic renal surgery
renal artery
|
Content Type |
Journal Article
|
Description | Hem-o-lok clips are commonly used for renal artery ligation in laparoscopic renal surgery. However, failure of the renal artery ligation clips is potentially fatal. A 61-year-old man underwent hand-assisted laparoscopic nephroureterectomy using a retroperitoneal approach for left ureteral carcinoma. One hour postoperatively, he was diagnosed with hemorrhagic shock. An immediate laparotomy revealed two closed, undamaged Hem-o-lok clips around the left renal artery. Pulsatile bleeding was observed, and the renal artery was immediately ligated with non-absorbable thread. We determined that the failure of the Hem-o-lok clips on the renal artery was caused by the lack of space between the two Hem-o-lok clips and the distal renal artery cuff beyond the distal clip. To prevent a potentially fatal failure of the renal artery ligation clips, one should maintain a sufficient space between the Hem-o-lok clips and an adequate distal renal artery cuff beyond the distal clip.
|
Journal Title |
The Journal of Medical Investigation
|
ISSN | 13496867
13431420
|
NCID | AA11166929
|
Publisher | Tokushima University Faculty of Medicine
|
Volume | 68
|
Issue | 3-4
|
Start Page | 393
|
End Page | 395
|
Sort Key | 393
|
Published Date | 2021-08
|
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
Publisher
|