Description | Purpose: Developmental dysplasia of the hip (DDH) presents a considerable surgical challenge in total hip arthroplasty (THA). Although the usefulness of computed tomography (CT)-based navigation in cup alignment has been reported, few reports have evaluated three-dimensional (3-D) cup positioning against the acetabulum specifically in patients with DDH. The purpose of this study was to evaluate the efficacy of a CT-based navigation system for alignment and spatial positioning of the cup in THA for patients with DDH. Methods: We reviewed 174 DDH THA cases in which CT-based navigation was used, and 75 cases in which a mechanical guide was used as a control group. Postoperative cup alignment and spatial positioning were evaluated by superimposition of a 3-D cup template onto the actual implanted cup using postoperative CT images, with pelvic coordinates matching the preoperative planning. Results: The proportion within the combined target zone (inclination and anteversion) was 97.7% in the navigation group and 61.3% in the non-navigation group. The mean absolute error between the intraoperative record and the postoperative measurement was 1.5° ± 1.3° for inclination and 2.1° ± 1.8° for anteversion in the navigation group. For acetabular cup positioning, the mean discrepancy between the preoperative planning and the postoperative measurements was 1.9+1.6 mm on the transverse axis, 2.8 ± 2.3 mm on the longitudinal axis, and 1.7 ± 1.3 mm on the sagittal axis. Conclusion: THA using a CT-based navigation system achieved quite high accuracy of cup alignment angles and spatial cup positioning in primary THA for patients with DDH.
|
Journal Title |
Journal of Orthopaedic Surgery
|
ISSN | 23094990
|
Publisher | Sage
|
Volume | 25
|
Issue | 3
|
Start Page | 1
|
End Page | 7
|
Published Date | 2017-08-29
|
Remark | 内容要旨・審査要旨・論文本文の公開
本論文は, 著者Takahiko Tsutsuiの学位論文として提出され, 学位審査・授与の対象となっている。 |
Rights | © The Author(s) 2017 This article is distributed under the terms of the Creative Commons Attribution-Non Commercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
|
EDB ID | |
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
ETD
|
MEXT report number | 甲第3127号
|
Diploma Number | 甲医第1361号
|
Granted Date | 2018-03-23
|
Degree Name |
Doctor of Medical Science
|
Grantor |
Tokushima University
|
departments |
University Hospital
Medical Sciences
|