Description | Objectives: When dentists adjust prostheses at the dental chairside, particulate matter (PM) from the dental material is dispersed. Little is known about the effective use of an extraoral vacuum (EOV) in preventing PM dispersal. This study aimed to evaluate the effective use of an EOV in preventing the dispersal of metal PM in dental offices.
Methods: The following experimental conditions were planned: the distance from the EOV to the metallic materials (50, 100, 150, and 200 mm), the horizontal angle between the long axis of the micromotor handpiece and EOV (0°, 45°, and 90°), and the operating time of the EOV (during grinding, during grinding and 1 min thereafter, during grinding and the preceding 1 min, 1 min before and after grinding, and during grinding). Carborundum and silicone points were used for grinding and PM dispersal. Diameters (0.3, 0.5, 1.0, and 3.0 μm) were measured using a laser particle counter. Results: Depending on the instrument used to grind, there were undetectable PMs of different diameters (Carborundum point: 0.3 and 0.5 μm, Silicone point: 0.3 μm). PMNs were reduced as the distance from the EOV to metal materials decreased. Operating the EOV before grinding along the long axis of the micromotor handpiece was effective in reducing the PMNs. Conclusion: PMNs dispersed when grinding metals were effectively reduced by positioning the EOV closer to the grinding surface (within 150 mm) along the long axis of the micromotor handpiece and operating the EOV before grinding. |
Journal Title |
Journal of Occupational Health
|
ISSN | 13489585
|
NCID | AA11090645
|
Publisher | Japan Society for Occupational Health|Wiley
|
Volume | 65
|
Issue | 1
|
Start Page | e12412
|
Published Date | 2023-06-22
|
Rights | This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
|