Fogarty catheter for OLV of a neonate
Author
Sasaki, Hideto Tokushima University
Sogabe, Yohei Tokushima University
Hirota, Kentaro University Hospital
Honda, Yasuto Tokushima University
Keywords
neonatal and infantile one-lung ventilation
slip joint section
Fogarty catheter
Content Type
Journal Article
Description
Here, we report two cases involving a neonate and child in which a slip joint section was used to thread a Fogarty catheter into the endotracheal tube for one-lung ventilation (OLV). Both the neonate and infant required OLV, and were placed under general anesthesia. A Fogarty catheter was used for OLV. The Fogarty catheter was passed into the intraluminal side of the endotracheal tube through a slip joint section. OLV was maintained successfully without severe air leakage or Fogarty catheter displacement. The neonate had been intubated pre-operatively with a 3.5-mm inner diameter endotracheal tube, and we used that tube. These cases indicate that the technique can be applied to pre-operatively intubated patients and does not require surgeons to exchange endotracheal tubes. Use of the slip joint section technique facilitates Fogarty catheter fixation without additional dead space.
Journal Title
The Journal of Medical Investigation
ISSN
13496867
13431420
NCID
AA11166929
Publisher
Tokushima University Faculty of Medicine
Volume
68
Issue
1-2
Start Page
209
End Page
212
Sort Key
209
Published Date
2021-02
DOI (Published Version)
URL ( Publisher's Version )
FullText File
language
eng
TextVersion
Publisher
departments
University Hospital
Medical Sciences