ID | 109458 |
Title Alternative | T1-CUBE法と3D-SPGR法による脳腫瘍造影増強効果の比較
Brain Tumor CE on T1-Cube versus 3D SPGR
|
Author |
Mungunkhuyag, Majigsuren
The University of Tokushima
Takeuchi, Mayumi
The University of Tokushima
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Otomi, Yoichi
The University of Tokushima
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Uyama, Naoto
The University of Tokushima
Nagahiro, Shinji
The University of Tokushima
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Harada, Masafumi
The University of Tokushima
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
|
Keywords | 三次元 fast spoiled gradient recall acquisition in steady state (3D FSPGR)
脳腫瘍
造影磁気共鳴画像
T1-Cube シーケンス
brain tumor
contrast-enhanced magnetic resonance imaging (CE MRI)
T1-Cube sequence
3-dimensional fast spoiled gradient recall acquisition in steady state (3D FSPGR)
|
Content Type |
Thesis or Dissertation
|
Description | Purpose: T1-Cube (GE HealthCare) is a relatively new 3-dimensional (3D) fast spin-echo (FSE)-based magnetic resonance (MR) imaging sequence that uses a variable flip angle to acquire gap-free volume scans. We compared the gadolinium enhancement characteristics of a heterogeneous population of brain tumors imaged by T1-Cube and then 3D fast spoiled gradient recall acquisition in steady state (3D FSPGR) 3-tesla MR imaging to identify the superior modality for specific diagnostic purposes.
Methods: We examined 61 lesions from 32 patients using the 2 sequences after administration of gadopentetic acid (Gd-DTPA; 0.1 mmol/kg). Two neuroradiologists independently measured each lesion twice using a region-of-interest (ROI) method. We measured the contrast-to-noise ratio (CNR), the difference in signal intensity (SI) between the tumor and normal white matter relative to the standard deviation (SD) of the SI within the lesion, for both post-contrast 3D FSPGR and post-contrast T1-Cube images of the same tumor and compared modality-specific CNRs for all tumors and in subgroups defined by tumor size, enhancement ratio, and histopathology. Results: The mean CNR was significantly higher on T1-Cube images than 3D FSPGR images for the total tumor population (1.85 ± 0.97 versus 1.12 ± 1.05, P < 0.01) and the histologic types, i.e., metastasis (P < 0.01) and lymphoma (P < 0.05). The difference in CNR was even larger for smaller tumors in the metastatic group (4.95 to 23.5 mm2) (P < 0.01). In contrast, mean CNRs did not differ between modalities for high grade glioma and meningioma. Conclusions: Gadolinium enhancement of brain tumors was generally higher when imaged by T1-Cube than 3D FSPGR, and T1-Cube with Gd enhancement may be superior to 3D FSPGR for detecting smaller metastatic tumors. |
Journal Title |
Magnetic Resonance in Medical Sciences
|
ISSN | 18802206
13473182
|
NCID | AA12036292
AA11648770
|
Publisher | Japanese Society for Magnetic Resonance in Medicine
|
Volume | 15
|
Issue | 1
|
Start Page | 34
|
End Page | 40
|
Published Date | 2016-01-01
|
Remark | 内容要旨・審査要旨・論文本文の公開:
内容要旨・審査要旨 : LID201506251002.pdf 論文本文 : LID201601251001.pdf 本論文は, 著者Mungunkhuyag Majigsurenの学位論文として提出され, 学位審査・授与の対象となっている。 |
EDB ID | |
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
ETD
|
MEXT report number | 甲第2855号
|
Diploma Number | 甲医第1251号
|
Granted Date | 2015-05-28
|
Degree Name |
Doctor of Medical Science
|
Grantor |
Tokushima University
|
departments |
Medical Sciences
University Hospital
|