ID | 114291 |
Author |
Kobayashi, Makoto
National Institutes of Natural Sciences|SOKENDAI
Ogawa, Kunihiro
National Institutes of Natural Sciences|SOKENDAI
Isobe, Mitsutaka
National Institutes of Natural Sciences|SOKENDAI
Nishitani, Takeo
National Institutes of Natural Sciences
Kamio, Shuji
National Institutes of Natural Sciences
Fujiwara, Yutaka
National Institutes of Natural Sciences
Tsubouchi, Tomomi
National Institutes of Natural Sciences|SOKENDAI
Yoshihashi, Sachiko
Nagoya University
Uritani, Akira
Nagoya University
Sakama, Minoru
Tokushima University
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Osakabe, Masaki
National Institutes of Natural Sciences|SOKENDAI
|
Keywords | diamond detector
neutron
MCNP
PHITS
|
Content Type |
Journal Article
|
Description | The single crystal CVD diamond detector (SDD) was installed in the torus hall of the Large Helical Device (LHD) to measure neutrons with high time resolution and neutron energy resolution. The LiF foil with 95.62 % of 6Li isotope enrichment pasted on the detector was used as the thermal neutron convertor as the energetic ions of 2.0 MeV alpha and 2.7 MeV triton particles generated in LiF foil and deposited the energy into SDD.
SDD were exposed to the neutron field in the torus hall of the LHD during the 2nd campaign of the deuterium experiment. The total pulse height in SDD was linearly propotional to the neutron yield in a plasma operation in LHD over 4 orders of magnitude. The energetic alpha and triton were separately measured by SDD with LiF with the thickness of 1.9 μm, although SDD with LiF with the thickness of 350 μm showed a broadened peak due to the large energy loss of energetic particles generated in the bulk of LiF. The modeling with MCNP and PHITS codes well interpreted the pulse height spectra for SDD with LiF with different thicknesses. The results above demonstrated the sufficient time resolution and energy discrimination of SDD used in this work. |
Journal Title |
Journal of Instrumentation
|
ISSN | 17480221
|
NCID | AA12456425
|
Publisher | IOP Publishing
|
Volume | 14
|
Issue | 9
|
Start Page | C09039
|
Published Date | 2019-09-23
|
Remark | This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1748-0221/14/09/c09039.
|
EDB ID | |
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
Author
|
departments |
Medical Sciences
|