Keywords | 3D printed model
CBCT
|
Content Type |
Journal Article
|
Description | Objectives: To determine the accuracy of three-dimensional (3D) printed models fabricated from cone-beam computed tomography (CBCT) scans of human mandibular dry skulls in comparison with models derived from intraoral scanner (IOS) data.
Materials and Methods: Six human mandibular dry skulls were scanned by IOS and CBCT. Digital models (DMs) constructed from the IOS and CBCT data were fabricated physically using a 3D printer. The width and thickness of individual teeth and intercanine and molar widths were measured using a digital caliper. The accuracy of the DMs was compared between IOS and CBCT. Paired t-tests were used for intergroup comparisons. Results: All intraclass correlation coefficient values for the three measurements (mesial-distal, buccal-lingual, width) exceeded 0.9. For the mandibular teeth, there were significant discrepancies in model accuracy between the IOS (average discrepancies of 0.18 ± 0.08 mm and 0.16 ± 0.12 mm for width and thickness, respectively) and CBCT (0.28 ± 0.07 mm for width, 0.37 ± 0.2 mm for thickness; P < .01). Intercanine (P = .38) and molar widths (P = .41) showed no significant difference between groups. Conclusions: There was a statistically significant difference in the accuracy of DMs obtained from CBCT and IOS; however, this did not seem to result in any important clinical difference. CBCT could be routinely used as an orthodontic diagnostic tool and for appliance construction. |
Journal Title |
The Angle Orthodontist
|
ISSN | 19457103
00033219
|
NCID | AA00525451
|
Publisher | The EH Angle Education and Research Foundation
|
Volume | 92
|
Issue | 6
|
Start Page | 722
|
End Page | 727
|
Published Date | 2022-07-19
|
EDB ID | |
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
Publisher
|
departments |
Oral Sciences
|