ID | 116066 |
Author | |
Keywords | Flash glucose monitoring
Self-monitoring of blood glucose
FreeStyle Libre
Type 2 diabetes mellitus
Diabetes treatment satisfaction questionnaire
Diabetes therapy-related quality of life questionnaire
|
Content Type |
Journal Article
|
Description | For adequate diagnosis and treatment for diabetes, there have been Self-Monitoring of Blood Glucose (SMBG), Continuous Glucose Monitoring (CGM) and Flash Glucose Monitoring (FGM).By applying FreeStyle Libre, many patients with diabetes mellitus have obtained better glucose variability. FGM can also contribute treatment satisfaction, which is evaluated by Diabetes Treatment Satisfaction Questionnaire (DTSQ) and Diabetes Therapy-Related Quality of Life (DTR-QOL) questionnaire. A report for patients with Type 2 Diabetes Mellitus (T2DM) showed that FGM continuation for 3 months contributed significant reduction of HbA1c and successive 3 months without FGM revealed stable HbA1c value, suggesting clinical psychological effect of FGM.
|
Journal Title |
GSL Journal of Nutrition and Metabolism
|
Publisher | Global Scientific Library
|
Volume | 2
|
Issue | 1
|
Published Date | 2021-03-27
|
Rights | This work is licensed under a Creative Commons Attribution 4.0 International License(https://creativecommons.org/licenses/by-nc-sa/4.0/).
|
FullText File | |
language |
eng
|
TextVersion |
Publisher
|
departments |
Medical Sciences
|