ID | 117203 |
Title Alternative | Monitoring of Bacterial-contamination of Dental Unit Water Lines using ATP-bioluminescence
Bacterial-contamination Monitoring
|
Author |
Watanabe, Akari
Tokushima University
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Yokota, Kenji
Okayama University
Matsuyama, Miwa
Tokushima University
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Kokeguchi, Susumu
Okayama University
|
Keywords | ATP bioluminescence
Dental unit water line
Bacteria
Contamination
Infection control
ATP-bioluminescence analysis
Bacteria contamination
|
Content Type |
Journal Article
|
Description | Bacterial contamination of dental unit waterlines (DUWLs) was evaluated by using ATP-bioluminescence analysis and conventional culture method. Water samples (n=44) from DUWLs were investigated for heterotrophic bacteria by culture on R2A agar, which ranged from 1.4×103 to 2.7×105 CFU/mL. The ATP-bioluminescence results for DUWL samples were ranged from 6 to 1189 RLU and obtained within one minutes. These results were well correlated with the culture results (r=0.727-0.855). We conclude that differences in the bacterial contamination of each water supply were confirmed by the ATP-bioluminescence assay. This method would be potentially useful for rapid and simple monitoring of DUWL bacterial contamination.
|
Journal Title |
Journal of Hospital Infection
|
ISSN | 01956701
|
NCID | AA00258209
AA11538375
|
Publisher | The Healthcare Infection Society|Elsevier
|
Volume | 94
|
Issue | 4
|
Start Page | 393
|
End Page | 396
|
Published Date | 2016-08-06
|
Rights | © 2016. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
|
EDB ID | |
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
Author
|
departments |
Oral Sciences
|