Title Alternative | 脊椎椎弓根スクリュー誤挿入後,再挿入を行った際の引き抜き強度についての研究
|
Author |
Goda, Yuichiro
Tokushima University
Toki, Shunichi
Tokushima University
Suzuki, Daisuke
Sapporo Medical University
Kobayashi, Takuma
Sapporo Medical University
Matsuura, Tetsuya
Tokushima University
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Fujimiya, Mineko
Sapporo Medical University
Hutton, Williams C.
Emory University
Fukui, Yoshihiro
Tokushima University
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
Sairyo, Koichi
Tokushima University
Tokushima University Educator and Researcher Directory
KAKEN Search Researchers
|
Keywords | malpositioned screw
pedicle screw
pullout strength
redirected screw
thoracolumbar spine
|
Content Type |
Thesis or Dissertation
|
Description | Screw malposition, such as lateral wall breach or end-plate breach, is one of the main pitfalls of inserting pedicle screws.
Methods: From 17 fresh spines 54 vertebrae were harvested. In each vertebra on one pedicle the screw was inserted correctly down the axis of the pedicle, while on the other pedicle the screw was inserted to breach the lateral wall or the end-plate. The 18 pedicle screws that breached the lateral wall were then removed and re-directed along the correct axis of the pedicle. The 18 pedicle screws that breached the end-plate were removed and re-directed along the correct axis of the pedicle. The 18 other pedicle screws that had breached the end-plate were not removed. The pullout force of pedicle screws was measured. Results: 1) The mean pullout strength for the re-directed screws following lateral wall breach was 24.0% less as compared to the correctly aligned screws; 2) The mean pullout strength for the re-directed screws following end-plate breach was 23.3% less as compared to the correctly aligned screws; 3) The mean pullout strength for the pedicle screws end-plate breach was 7.6% less as compared to the correctly aligned screws. Conclusion: The pullout strength of re-directed pedicle screws after either a lateral pedicle breach or end-plate breach is significantly less than the pullout strength of correctly aligned screw. A pedicle screw that is not re-directed after end-plate breach is weaker than a pedicle screw correctly aligned, however the difference is not significant. |
Journal Title |
Spine
|
ISSN | 03622436
|
NCID | AA0084801X
AA12431865
|
Publisher | Wolters Kluwer
|
Volume | 41
|
Issue | 15
|
Start Page | 1218
|
End Page | 1223
|
Published Date | 2016-08-01
|
Remark | 内容要旨・審査要旨・論文本文の公開:
内容要旨・審査要旨 : LID201701051001.pdf 論文本文 : k2996_fulltext.pdf 本論文は, 著者Yuichiro Godaの学位論文として提出され, 学位審査・授与の対象となっている。 |
Rights | Copyright: © 2016. Wolters Kluwer Health, Inc.
This manuscript version is made available under the CC-BY-NC 4.0 license http://creativecommons.org/licenses/by-nc/4.0/ |
EDB ID | |
DOI (Published Version) | |
URL ( Publisher's Version ) | |
FullText File | |
language |
eng
|
TextVersion |
ETD
|
MEXT report number | 甲第2996号
|
Diploma Number | 甲医第1301号
|
Granted Date | 2016-10-27
|
Degree Name |
Doctor of Medical Science
|
Grantor |
Tokushima University
|
departments |
University Hospital