ID 110813
著者
タケガミ, カズキ Graduate School of Health Sciences, Tokushima University|Yamaguchi University Hospital
林, 裕晃 Graduate School of Biomedical Sciences, Tokushima University KAKEN研究者をさがす
オキノ, ヒロキ Graduate School of Health Sciences, Tokushima University
キモト, ナツミ Graduate School of Health Sciences, Tokushima University
マエハタ, イツミ School of Health Sciences, Tokushima University
金澤, 裕樹 Graduate School of Biomedical Sciences, Tokushima University 徳島大学 教育研究者総覧 KAKEN研究者をさがす
オカザキ, トオル Nagase Landauer, LTD.
ハシズメ, タクヤ Nagase Landauer, LTD.
コバヤシ, イクオ Nagase Landauer, LTD.
キーワード
OSL dosimeter
CdTe detector
Patient exposure dose measurement
Diagnostic X-rays
資料タイプ
学術雑誌論文
抄録
Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1–20 cm), and a CdTe X-ray spectrometer assuming one pixel of the X-ray imaging detector. Then, with the following two experimental settings, corresponding X-ray spectra were measured with 40–120 kVp and 0.5–1000 mAs at a source-to-detector distance of 100 cm: (1) X-rays penetrating a soft-tissue-equivalent phantom with the OSL dosimeter attached directly on the phantom, and (2) X-rays penetrating only the soft-tissue-equivalent phantom. Next, the energy fluence and errors in the fluence were calculated from the spectra. When the energy fluence with errors concerning these two experimental conditions was estimated to be indistinctive, we defined the condition as the OSL dosimeter not being identified on the X-ray image. Based on our analysis, we determined the identification limit of the dosimeter. We then compared our results with those for the general irradiation conditions used in clinics. We found that the OSL dosimeter could not be identified under the irradiation conditions of abdominal and chest radiography, namely, one can apply the OSL dosimeter to measurement of the exposure dose in the irradiation field of X-rays without disturbing medical images.
掲載誌名
Radiological Physics and Technology
ISSN
18650333
18650341
cat書誌ID
AA12236881
出版者
Springer Japan
9
2
開始ページ
286
終了ページ
292
並び順
286
発行日
2016-06-03
備考
Copyright © Japanese Society of Radiological Technology and Japan Society of Medical Physics 2016
The final publication is available at Springer via http://dx.doi.org/10.1007/s12194-016-0362-5.
EDB ID
出版社版URL
フルテキストファイル
言語
eng
著者版フラグ
著者版
部局
医学系