ID | 115825 |
タイトル別表記 | Molecular analysis for bacterial contamination
|
著者 |
Kokeguchi, Susumu
Okayama University
|
キーワード | Bacterial contamination
Dental unit water line
Molecular analysis
PCR-DGGE
|
資料タイプ |
学術雑誌論文
|
抄録 | Bacterial contamination in dental unit waterlines (DUWLs) was evaluated by molecular techniques in addition to the conventional culture method. Water samples (n=8) from DUWLs were investigated for heterotrophic bacteria by culture method using R2A agar. The selected bacterial antibiotic-resistance genes and Legionella species-specific 16SrDNA were identified by PCR. The profiles of bacterial contamination in DUWLs were further identified by PCR-DGGE. In this study, no antibiotic-resistant or Legionella genes were detected. Polycyclic aromatic hydrocarbon-degrading bacterium, Novosphingobium sp. was the most prevalent in DUWLs. Conventional PCR and PCR-DGGE were shown to be potentially useful for monitoring of bacterial contamination in DUWLs.
|
掲載誌名 |
New Microbiologica
|
ISSN | 11217138
|
cat書誌ID | AA11980981
|
出版者 | EDIMES
|
巻 | 39
|
号 | 2
|
開始ページ | 143
|
終了ページ | 145
|
発行日 | 2016-04
|
EDB ID | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
歯学系
|