ID | 115847 |
著者 |
Ogawa, Y
Tokushima University
Nakaishi, E
Tokushima University
|
資料タイプ |
学術雑誌論文
|
抄録 | The diameter of the ventricular assist pump and cooling pump for electrical devices like servers is about a dozen millimetres and these kinds of pumps belong to the mini pump. The internal flow condition of the mini centrifugal pump has to be clarified because there are so many types of mini pumps according to special specifications and shapes. Therefore, in this research, an open impeller was adopted as a mini centrifugal pump with 55mm impeller diameter in consideration of reduction in impeller manufacturing cost and its internal flow was investigated. Since the outlet angle of the test impeller is large, the maximum efficiency flow rate moves to a large flow rate and the relatively high head and efficiency were obtained in large flow rate region. In the present paper, the velocity and vorticity distribution near the volute tongue are shown and the internal flow in the mini centrifugal pump is clarified based on the PIV measurement results.
|
掲載誌名 |
IOP Conference Series: Earth and Environmental Science
|
ISSN | 17551315
17551307
|
出版者 | IOP Publishing
|
巻 | 240
|
号 | 3
|
開始ページ | 032026
|
発行日 | 2019-03-28
|
権利情報 | Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence(https://creativecommons.org/licenses/by/3.0/). Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
理工学系
|