キーワード | calibration factor
eye lens dose
IVR
OSL dosimeter
scattered x-ray
|
資料タイプ |
学術雑誌論文
|
抄録 | The eye lens is a sensitive organ of which an x‐ray exposure dose should be managed during interventional radiology (IVR). In the actual situations, the eye lens is exposed to scattered x‐rays; they have different from the standard x‐ray energies which are used for general dose calibration of the dosimeter. To perform precise dose measurement, the energy dependence of the dosimeter should be properly accounted for when calibrating the dosimeter. The vendor supplies a calibration factor using 80‐kV diagnostic x‐rays under a free‐air condition. However, whether it is possible to use this calibration factor to evaluate the air kerma during the evaluation of the eye lens dose is unclear. In this paper, we aim to precisely determine calibration factors, and also examine the possible application of using a vendor‐supplied calibration factor. First, the x‐ray spectrum at the eye lens position during fluoroscopy was measured with a CdTe x‐ray spectrometer. We mimicked transfemoral cardiac catheterization using a human‐type phantom. Second, we evaluated the doses and calibration factors at three dosimetric points: front and back of protective goggles, and the front of the head (eye lens position). We used the measured x‐ray spectrum to determine the incident photon distribution in the eye lens regions, and x‐ray spectra corresponding to the dosimetric points around the eye lens were estimated using Monte Carlo simulation. Although the calibration factors varied with dosimetric positions, we found that the factors obtained were similar to the vendor‐supplied calibration factor. Furthermore, based on the experiment, we propose a practical way to calibrate an OSL dosimeter in an actual clinical situation. A person evaluating doses can use a vendor‐supplied calibration factor without any corrections for energy dependences, only when they add a systematic uncertainty of 5%. This evidence will strongly support actual exposure dose measurement during a clinical study.
|
掲載誌名 |
Journal of Applied Clinical Medical Physics
|
ISSN | 15269914
|
cat書誌ID | AA12034060
|
出版者 | Wiley Periodicals|American Association of Physicists in Medicine
|
巻 | 21
|
号 | 11
|
開始ページ | 263
|
終了ページ | 271
|
発行日 | 2020-10-14
|
権利情報 | This is an open access article under the terms of the Creative Commons Attribution License(https://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
医学系
|