ID | 117910 |
著者 |
Nishimura, Madoka
Tokushima University
Nakaya, Yukari
Tokushima University
Kashimoto, Mao
Tokushima University
|
キーワード | Perchlorate
ion chromatography
river water
solid phase extraction
preconcentration
|
資料タイプ |
学術雑誌論文
|
抄録 | This paper proposes a simple ion chromatographic approach to determine trace amounts of perchlorate in river water samples. Determination of the trace perchlorate by ion chromatography typically faces two challenges: interference by matrix ions such as chloride, nitrate, and sulfate in the samples and insufficient detection sensitivity. In the present study, online pretreatment of the samples with an OnGuard II Ba/Ag/H disposable sample pretreatment cartridge prevented the sulfate peak tailing from overlapping with the perchlorate peak on the chromatogram. In addition, the matrix removal enabled as large as 10 mL of sample to be loaded into a high exchange capacity anion concentrator, significantly improving perchlorate's detection sensitivity. The proposed approach achieved a detection limit (S/N = 3) of 0.046 µg L-1 without using a costly mass spectrometer and successfully determined sub µg L-1 levels of perchlorate in river water.
|
掲載誌名 |
Analytical Sciences
|
ISSN | 13482246
09106340
|
cat書誌ID | AA10500785
|
出版者 | The Japan Society for Analytical Chemistry|Springer Nature
|
巻 | 39
|
号 | 5
|
開始ページ | 689
|
終了ページ | 694
|
発行日 | 2023-01-12
|
備考 | This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use (https://www.springernature.com/gp/open-research/policies/accepted-manuscript-terms), but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s44211-022-00262-9
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
著者版
|
部局 |
理工学系
薬学系
|