ID | 119381 |
著者 |
Welti, Sophia E.
Hiroshima University
Yasuda, Hiroshi
Hiroshima University
|
キーワード | Radiochromic
PVA
Iodine
Temperature
Gel
PAISiN
X-rays
|
資料タイプ |
学術雑誌論文
|
抄録 | Radiochromic materials have good potentials for the prompt on-site detection of accidental high-dose exposure. One of the drawbacks of using these materials on various occasions is that they cannot generally be reused after coloration. In the present study, a recently developed radiochromic complex composed of polyvinyl alcohol, iodide, and silica nanoparticles named “PAISiN,” was repeatedly annealed at 40 °C for 3 h and irradiated with X-rays (160 kV, 6.3 mA) at 8, 4 and 2 Gy(H2O) each up to a total dose of 24 Gy. RGB color images of the PAISiN samples were acquired with a flatbed scanner and analyzed using image processing software. As results, PAISiN showed reproducible responses in all fractionated dose levels. Additionally, it was confirmed that the PAISiN samples annealed after repetitive irradiation maintained a stable white color for 12 days at room temperature. From these findings, it is expected that PAISiN could be used repeatedly and effectively for personal monitoring of accidental high-dose exposure under normal indoor conditions.
|
掲載誌名 |
Radiation Measurements
|
ISSN | 13504487
18790925
|
cat書誌ID | AA11020151
AA11538794
|
出版者 | Elsevier
|
巻 | 175
|
開始ページ | 107173
|
発行日 | 2024-05-21
|
権利情報 | This is an open access article under the CC BY-NC license (https://creativecommons.org/licenses/by-nc/4.0/).
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
放射線総合センター
|