直近一年間の累計
アクセス数 : ?
ダウンロード数 : ?
ID 119470
タイトル別表記
Spinal MRI in lumboperitoneal shunt
著者
Tanaka, Tatsuya International University of Health and Welfare Narita Hospital|New Yachimata General Hospital
Sashida, Ryohei International University of Health and Welfare Narita Hospital
Hirokawa, Yu International University of Health and Welfare Narita Hospital
Wakamiya, Tomihiro International University of Health and Welfare Narita Hospital
Michiwaki, Yuhei International University of Health and Welfare Narita Hospital
Shimoji, Kazuaki International University of Health and Welfare Narita Hospital
Suehiro, Eiichi International University of Health and Welfare Narita Hospital
Onoda, Keisuke International University of Health and Welfare Narita Hospital
Yamane, Fumitaka International University of Health and Welfare Narita Hospital
Matsuno, Akira International University of Health and Welfare Narita Hospital
Morimoto, Tadatsugu Saga University
キーワード
hydrocephalus
programmable valve
lumboperitoneal shunt
artifact
magnetic resonance imaging
資料タイプ
学術雑誌論文
抄録
Background : Adjustable shunt valves that have been developed for managing hydrocephalus rely on intrinsically magnetic components ; thus, artifacts with these valves on magnetic resonance imaging (MRI) are inevitable. No studies on valve-induced artifacts in lumboperitoneal shunt (LPS) surgery have been published. Therefore, this study aimed to evaluate valve-induced artifacts in LPS. Methods : We retrospectively reviewed all MRIs obtained between January 2023 and June 2023 in patients with an implanted Codman CERTAS Plus adjustable shunt valve (Integra Life Sciences, Princeton, New Jersey, USA). The valve was placed < 1 cm subcutaneously on the paravertebral spinal muscle of the back, with its long axis perpendicular to the body axis. The scans were performed using a Toshiba Medical Systems 1.5 Tesla scanner. The in-plane artifact sizes were assessed as the maximum distance of the artifact from the expected region of the back. Results : All spinal structures or spinal cords can be recognized, even with valve–induced artifacts. The median maximum valve-induced artifact distance on T1-weighted axial imaging was 25.63 mm (mean, 25.98 mm ; range, 22.24–30.94 mm). The median maximum valve-induced artifact distance on T2-weighted axial imaging was 25.56 mm (mean, 26.27 mm ; range, 21.83–29.53 mm). Conclusion : LPS surgery with adjustable valve implantation on paravertebral muscles did not cause valve-induced artifacts in the spine and spinal cord. We considered that LPS could simplify the postoperative care of these patients.
掲載誌名
The Journal of Medical Investigation
ISSN
13496867
13431420
cat書誌ID
AA11166929
出版者
Tokushima University Faculty of Medicine
71
1-2
開始ページ
154
終了ページ
157
並び順
154
発行日
2024-02
出版社版DOI
出版社版URL
フルテキストファイル
言語
eng
著者版フラグ
出版社版