直近一年間の累計
アクセス数 : ?
ダウンロード数 : ?
ID 83262
著者
岡村, 誠介 Second Department of Internal Medicine, The University of Tokushima School of Medicine
ツツイ, アケミ Second Department of Internal Medicine, The University of Tokushima School of Medicine
六車, 直樹 Second Department of Internal Medicine, The University of Tokushima School of Medicine 徳島大学 教育研究者総覧 KAKEN研究者をさがす
イチカワ, ソウイチ Second Department of Internal Medicine, The University of Tokushima School of Medicine
曽我部, 正弘 Second Department of Internal Medicine, The University of Tokushima School of Medicine 徳島大学 教育研究者総覧 KAKEN研究者をさがす
オオキタ, ヨシオ Second Department of Internal Medicine, The University of Tokushima School of Medicine
フクダ, タモツ Second Department of Internal Medicine, The University of Tokushima School of Medicine
ハヤシ, シゲヒト Second Department of Internal Medicine, The University of Tokushima School of Medicine
岡久, 稔也 Second Department of Internal Medicine, The University of Tokushima School of Medicine 徳島大学 教育研究者総覧 KAKEN研究者をさがす
シバタ, ヒロシ Second Department of Internal Medicine, The University of Tokushima School of Medicine
伊東, 進 Second Department of Internal Medicine, The University of Tokushima School of Medicine 徳島大学 教育研究者総覧
佐野, 壽昭 First Department of Pathology, The University of Tokushima School of Medicine 徳島大学 教育研究者総覧 KAKEN研究者をさがす
キーワード
endoscopic ultrasonography
ultrasonic miniprobe
gastric cancer
資料タイプ
学術雑誌論文
抄録
To determine the utility and limitations of an ultrasonic miniprobe (UMP) in the staging of gastric cancer, we evaluated 46 patients who underwent endoscopic ultrasonography (EUS) using an UMP and who were histologically determined to have gastric cancers. In every case, UMP findings were compared with histopathological findings after treatment. The total accuracy of UMP relative to the depth of tumor invasion was71.7% (33/46 cases). Accuracy with respect to T1-m tumor diagnosis was 75.7% (22/29cases), and for T1-sm, 76.9% (10/13 cases), but accuracy for T2 tumor diagnosis was low, due to ultrasound attenuation. When the analysis was carried out based on the size of tumor, the accuracy for UMP was 50.0% (9/18cases) for all tumors over 20mm and 85.7%(24/28 cases) for all tumors smaller than 20mm. We conclude that UMP is suitable for investigation of tumor extension when the lesion is superficial and / or small gastric cancers which do not cause ultrasonic attenuation, but not when the tumor is large or located in certain sites, although conventional EUS is useful in some of these cases.
掲載誌名
The journal of medical investigation : JMI
ISSN
13431420
cat書誌ID
AA11166929
46
1-2
開始ページ
49
終了ページ
53
並び順
49
発行日
1999
備考
EDB ID
フルテキストファイル
言語
eng
部局
医学系