ID | 115520 |
著者 |
中西, 信人
Tokushima University
|
資料タイプ |
学術雑誌論文
|
抄録 | Reverse triggering is respiratory entrainment triggered by the ventilator especially seen among heavily sedated patients. We confirmed reverse triggering induced by auto-triggering in lightly sedated patient through an esophageal pressure monitoring. The reverse triggering frequently caused breath stacking with increased tidal volume. Physicians should be aware, even at an optimal level of sedation, that reverse triggering can develop, possibly caused by auto-triggering.
|
掲載誌名 |
Journal of Intensive Care
|
ISSN | 20520492
|
出版者 | BioMed Central|Springer Nature
|
巻 | 6
|
開始ページ | 41
|
発行日 | 2018-07-28
|
権利情報 | This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
医学系
病院
|