ID | 115001 |
タイトル別表記 | Radiation exposure to the hand
|
著者 |
Ikuma, Hisanori
Kagawa Rosai Hospital
Tokashiki, Takuya
Kagawa Rosai Hospital
Maehara, Takashi
Kagawa Rosai Hospital
長町, 顕弘
Tokushima University
|
キーワード | Radiation exposure
Spinal procedure
Fluoroscopy
Hand
Fingers
|
資料タイプ |
学術雑誌論文
|
抄録 | Study Design: Prospective study.
Purpose: During fluoroscopically guided spinal procedure, the hands of spinal surgeons are placed close to the field of radiation and may be exposed to ionizing radiation. This study directly measured the radiation exposure to the hand of a spinal interventionalist during fluoroscopically guided procedures. Overview of Literature: Fluoroscopically guided spinal procedures have been reported to be a cause for concern due to the radiation exposure to which their operators are exposed. Methods: This prospective study evaluated the radiation exposure of the hand of one spinal interventionalist during 52 consecutive fluoroscopic spinal procedures over a 3-month period. The interventionalist wore three real-time dosimeters secured to the right forearm, under the lead apron over the chest, and outside the lead apron over the chest. Additionally, one radiophotoluminescence glass dosimeter was placed under the lead apron over the left chest and one ring radiophotoluminescence glass dosimeter was worn on the right thumb. The duration of exposure and radiation dose were measured for each procedure. Results: The average radiation exposure dose per procedure was 14.9 µSv, 125.6 µSv, and 200.1 µSv, inside the lead apron over the chest, outside the lead apron over the chest, and on the right forearm, respectively. Over the 3-month period, the protected radiophotoluminescence glass dosimeter over the left chest recorded less than the minimum reportable dose, whereas the radiophotoluminescence glass ring dosimeter recorded 368 mSv for the thumb. Conclusions: Our findings indicated that the cumulative radiation dose measured at the dominant hand may exceed the annual dose limit specified by the International Commission on Radiological Protection. Spinal interventionalists should take special care to limit the duration of fluoroscopy and radiation exposure. |
掲載誌名 |
Asian Spine Journal
|
ISSN | 19761902
19767846
|
cat書誌ID | AA12329596
|
出版者 | Korean Society of Spine Surgery
|
巻 | 11
|
号 | 1
|
開始ページ | 75
|
終了ページ | 81
|
発行日 | 2017-02-17
|
権利情報 | This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
医学系
病院
|