直近一年間の累計
アクセス数 : ?
ダウンロード数 : ?
ID 117554
著者
木下, 光博 Tokushima Red Cross Hospital
Hiraoka, Junichiro Tokushima Red Cross Hospital
Takechi, Katsuya Tokushima Red Cross Hospital
Akagawa, Yoko Tokushima Red Cross Hospital
尾﨑, 享祐 Tokushima Red Cross Hospital
Ohnishi, Norio Tokushima Red Cross Hospital
Tani, Hayato Tokushima Red Cross Hospital
キーワード
Central venous access port
Unsuccessful removal
Indwelling period
Forearm
Adult oncologic patients
資料タイプ
学術雑誌論文
抄録
Purpose: To evaluate the risk factors for unsuccessful removal of a central venous access port (CV port) implanted in the forearm of adult oncologic patients.
Materials and methods: This study included 97 adult oncologic patients (51 males, 46 females; age range, 30–88 years; mean age, 63.7 years) in whom removal of a CV port implanted in the forearm was attempted at our hospital between January 2015 and May 2021. Gender, age at removal, body mass index, and diagnosis were examined as patient characteristics; and indwelling period, indwelling side, and indication for removal were examined as factors associated with removal of a CV port. These variables were compared between successful and unsuccessful cases using univariate analysis. Then, multivariate analysis was performed to identify independent risk factors for unsuccessful removal of a CV port using variables with a significant difference in the univariate analysis. A receiver-operating characteristics (ROC) curve was drawn for significant risk factors in the multivariate analysis and the Youden index was used to determine the optimum cut-off value for predicting unsuccessful removal of a CV port.
Results: Removal of CV ports was successful in 79 cases (81.4%), but unsuccessful in 18 cases (18.6%) due to fixation of the catheter to the vessel wall. Multivariate logistic regression analysis showed that the indwelling period (odds ratio 1.048; 95% confidence interval 1.026–1.070; P < 0.0001) was a significant independent risk factor for unsuccessful removal of a CV port. ROC analysis showed that the cut-off value for successful removal was 41 months, and 54% of cases with an indwelling period > 60 months had unsuccessful removal.
Conclusion: The indwelling period is an independent risk factor for unsuccessful removal of a CV port implanted in the forearm of adult oncologic patients, with a cut-off of 41 months.
掲載誌名
Japanese Journal of Radiology
ISSN
1867108X
18671071
cat書誌ID
AA12375935
出版者
Japan Radiological Society|Springer Nature
40
4
開始ページ
412
終了ページ
418
発行日
2021-11-15
権利情報
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.