ID | 114012 |
著者 |
Jeon, Min-Gyu
Korea Maritime and Ocean University|Tokushima University
Doh, Deog-Hee
Korea Maritime and Ocean University
|
キーワード | Methane-Air premixed flame
computed tomography-tunable diode laser absorption spectroscopy
temperature
concentration
burner
exhaust gas
|
資料タイプ |
学術雑誌論文
|
抄録 | In this study, the temperature distribution of the Methane-Air premixed flame was measured. In order to enhance the measurement accuracy of the CT-TDLAS (Computed tomography-tunable diode laser absorption spectroscopy), the SMART (simultaneous multiplicative algebraic reconstruction technique) algorithm has been adopted. Further, the SLOS (summation of line of sight) and the CSLOS (corrective summation of line of sight) methods have been adopted to increase measurement accuracies. It has been verified that the relative error for the temperatures measured by the thermocouples and calculated by the CT-TDLAS was about 10%.
|
掲載誌名 |
Applied Sciences
|
ISSN | 20763417
|
出版者 | MDPI
|
巻 | 9
|
号 | 22
|
開始ページ | 4955
|
発行日 | 2019-11-18
|
権利情報 | © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
理工学系
|