キーワード | steel elemental analysis
sample temperature effect
SP-LIBS
collinear long-short DP-LIBS
|
資料タイプ |
学術雑誌論文
|
抄録 | Laser induced breakdown spectroscopy (LIBS) has been investigated as a potential multi-element quantitative analysis tool for the quality control of on-line steel production. This research investigated influence of sample temperature on steel sample measurement using collinear long-short dual-pulse LIBS (long-short DP-LIBS) and single-pulse LIBS (SP-LIBS). The standard steel sample has been uniformly heated in a muffle furnace from 20°C to 700°C. The experimental results show that sample temperature has significantly effect on measurement result using SP-LIBS. However, long-short DP-LIBS can effectively reduce the sample temperature effect on measurement result. The detection characteristics of long-short DP-LIBS and SP-LIBS were compared using the intensity ratio of I Mn 404.136 nm/I Fe 400.524 nm and I Fe 402.187 nm/I Fe 400.524 nm under different delay time and different sample temperature conditions. The signal intensity and plasma temperature can be maintained higher and more stable for a period of time and at different sample temperature by long-short DP-LIBS with smaller error bar compared with that of SP-LIBS, which indicated long-short DP-LIBS has better measurement repeatability than SP-LIBS. The plasma temperature correction method was applied to compare the detection features of long-short DP-LIBS and SP-LIBS. The signal stability of long-short DP-LIBS measurement was improved significantly at different sample temperature with plasma temperature correction. These results demonstrated that the effect of sample temperature can be reduced using long-short DP-LIBS method to improve the on-line detection capability for steel measurement in
complex environment. |
掲載誌名 |
ISIJ International
|
ISSN | 09151559
13475460
|
cat書誌ID | AA10680712
|
出版者 | The Iron and Steel Institute of Japan
|
巻 | 60
|
号 | 8
|
開始ページ | 1724
|
終了ページ | 1731
|
発行日 | 2020-02-28
|
権利情報 | © 2020 The Iron and Steel Institute of Japan
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
理工学系
|