ID | 116928 |
著者 |
Sugiura, Toshihiko
Chiba University
Tanabe, Nobuhiro
Chiba University
Kusumoto, Masahiko
National Cancer Center
Kaneko, Masahiro
Tokyo Health Service Association
|
キーワード | Chronic thromboembolic pulmonary hypertension
computed tomography
contact surface ratio
U-Net
|
資料タイプ |
学術雑誌論文
|
抄録 | Enlargement of the pulmonary artery is a morphological abnormality of pulmonary hypertension patients. Diameters of the aorta and main pulmonary artery (MPA) are useful for predicting the presence of pulmonary hypertension. A major problem in the automatic segmentation of the aorta and MPA from non-contrast CT images is the invisible boundary caused by contact with blood vessels. In this study, we applied U-Net to the segmentation of the aorta and MPA from non-contrast CT images for normal and chronic thromboembolic pulmonary hypertension (CTEPH) cases and evaluated the robustness to the contacts between blood vessels. Our approach of the segmentation consists of three steps: (1) detection of trachea branch point, (2) cropping region of interest centered to the trachea branch point, and (3) segmentation of the aorta and MPA using U-Net. The segmentation performances were compared in seven methods: 2D U-Net, 2D U-Net with pre-trained VGG-16 encoder, 2D U-Net with pre-trained VGG-19 encoder, 2D Attention U-Net, 3D U-Net, an ensemble method of them, and our conventional method. The aorta and MPA segmentation methods using these U-Net achieved higher performance than a conventional method. Although the contact boundaries of blood vessels caused lower performance compared with the non-contact boundaries, the mean boundary distances were below about one pixel.
|
掲載誌名 |
Proceedings of SPIE
|
ISSN | 0277786X
|
cat書誌ID | AA10619755
|
出版者 | SPIE
|
巻 | 12033
|
開始ページ | 1203325
|
発行日 | 2022-04-04
|
備考 | Hidenobu Suzuki, Mikio Matsuhiro, Yoshiki Kawata, Toshihiko Sugiura, Nobuhiro Tanabe, Masahiko Kusumoto, Masahiro Kaneko, and Noboru Niki "Segmentation of aorta and main pulmonary artery of non-contrast CT images using U-Net for chronic thromboembolic pulmonary hypertension: evaluation of robustness to contacts with blood vessels", Proc. SPIE 12033, Medical Imaging 2022: Computer-Aided Diagnosis, 1203325 (4 April 2022); https://doi.org/10.1117/12.2612705
|
権利情報 | Copyright 2022 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
理工学系
|