ID | 110959 |
タイトル別表記 | 心血管イベント予測のための上腕動脈収縮期血圧左右差の最適なカットオフ値の開発と検証
|
著者 |
廣野, 明
徳島大学大学院医科学教育部(医学専攻)
Kageyama, Norihito
Tokushima Prefectural Miyoshi Hospital
Sumitomo, Masayuki
Tokushima Prefectural Miyoshi Hospital
Fujinaga, Hiroyuki
Tokushima Prefectural Central Hospital
|
キーワード | Inter-arm systolic blood pressure difference
cardiovascular risk
optimal cut-off value
ankle-brachial blood pressure index
|
資料タイプ |
学位論文
|
抄録 | Background: An inter-arm systolic blood pressure difference (IAD) is associated with cardiovascular disease. The aim of this study was to develop and validate the optimal cut-off value of IAD as a predictor of major adverse cardiac events in patients with arteriosclerosis risk factors.
Methods: From 2009 to 2014, 1076 patients who had at least one cardiovascular risk factor were included in the analysis. We defined 700 randomly selected patients as a development cohort to confirm that IAD was the predictor of cardiovascular events and to determine optimal cut-off value of IAD. Next, we validated outcomes in the remaining 376 patients as a validation cohort. The blood pressure (BP) of both arms measurements were done simultaneously using the ankle-brachial blood pressure index (ABI) form of automatic device. The primary endpoint was the cardiovascular event and secondary endpoint was the all-cause mortality. Results: During a median period of 2.8 years, 143 patients reached the primary endpoint in the development cohort. In the multivariate Cox proportional hazards analysis, IAD was the strong predictor of cardiovascular events (hazard ratio: 1.03, 95% confidence interval: 1.01–1.05, p = 0.005). The receiver operating characteristic curve revealed that 5 mmHg was the optimal cut-off point of IAD to predict cardiovascular events (p < 0.001). In the validation cohort, the presence of a large IAD (IAD ≥ 5 mmHg) was significantly associated with the primary endpoint (p = 0.021). Conclusions: IAD is significantly associated with future cardiovascular events in patients with arteriosclerosis risk factors. The optimal cut-off value of IAD is 5 mmHg. |
掲載誌名 |
Journal of Cardiology
|
ISSN | 09145087
|
cat書誌ID | AN10070473
|
出版者 | Japanese College of Cardiology|Elsevier
|
巻 | 71
|
号 | 1
|
開始ページ | 24
|
終了ページ | 30
|
発行日 | 2017-08-19
|
備考 | 内容要旨・審査要旨・論文本文の公開
本論文は, 著者Akira Hironoの学位論文として提出され, 学位審査・授与の対象となっている。 |
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
博士論文全文を含む
|
文科省報告番号 | 甲第3115号
|
学位記番号 | 甲医第1350号
|
学位授与年月日 | 2017-10-26
|
学位名 |
博士(医学)
|
学位授与機関 |
徳島大学
|
部局 |
病院
医学系
|