ID | 116184 |
タイトル別表記 | EVALUATION OF TORQUE MOMENT IN ESTHETIC BRACKETS
|
著者 |
Nakano, Taiji
Nihon University
Nakajima, Akira
Nihon University
Watanabe, Hiroto
Nihon University
Osada, Ayaka
Nihon University
Namura, Yasuhiro
Nihon University
Yoneyama, Takayuki
Nihon University
Motoyoshi, Mitsuru
Nihon University
|
キーワード | Torque moment
Third-order bend
Esthetic bracket
Bendable wire
Fracture point
Dental materials
|
資料タイプ |
学術雑誌論文
|
抄録 | Objectives: To examine the torque moment that occurs between esthetic brackets and bendable alloy (stainless steel [SS], titanium-molybdenum [Ti-Mo], and titanium-niobium [Ti-Nb]) wires.
Materials and Methods: This study examined ceramic (CR), zirconium oxide (ZC), polycarbonate (PC), and conventional metallic brackets (MT) (upper, 0.018-inch and 0.022-inch slots) combined with SS, Ti-Mo, and Ti-Nb wires using elastic module ligation. The torque moments delivered by various wire and bracket combinations were measured using a torque gauge apparatus. The wire torque angles at 5–40° were examined. Results: The torque value increased in the order of CR, ZC, MT, and PC brackets for both 0.018-inch and 0.022-inch slots. The fracture points of the CR and ZC brackets combined with SS and Ti-Mo wires were approximately more than 30° and 35°, respectively. No fracture points were detected in the combination of ZC brackets and Ti-Nb wires. Conclusions: The current study identified the material characteristics of CR, ZR, and PC brackets during torque tooth movements. The present results demonstrate a characteristic combined effect between different esthetic brackets and bendable alloy wires. |
掲載誌名 |
The Angle Orthodontist
|
ISSN | 19457103
00033219
|
cat書誌ID | AA00525451
|
出版者 | The EH Angle Education and Research Foundation
|
巻 | 91
|
号 | 5
|
開始ページ | 656
|
終了ページ | 663
|
発行日 | 2021-04-06
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
歯学系
|