ID | 116936 |
著者 |
Tanaka, Haruka
Tokushima University
Namikawa, Makoto
Tokushima University
Tomiyasu, Naoya
Tokushima University
|
キーワード | Ammonia
Denuder
Ammonia transfer device
Conductivity detection
Flow analysis
|
資料タイプ |
学術雑誌論文
|
抄録 | Gaseous ammonia (NH3) is a primary basic substance in the atmosphere, and its global emission has been increasing in recent decades. It is vital to continuously monitor the atmospheric NH3 to clarify the impact of NH3 on sensitive ecosystems. This paper proposes a simple gaseous NH3 monitor utilizing a parallel plate wet denuder (PPWD) and a conductometric flow injection analysis (FIA) with an ammonia transfer device (ATD). In the present study, water-soluble basic gases, NH3, are selectively detected by the conductivity detector (CD). The ATD-CD ammonium detector requires no coloring reagents commonly used in FIA. Five-day field measurement of ambient NH3 was successfully performed with 30 min time resolution. All the air samples over the observation period (n = 186) contained NH3 above the limit of quantification (11.4 nmol m−3). The NH3 data showed excellent agreement with the values using ion chromatography in the field measurements.
|
掲載誌名 |
Talanta Open
|
ISSN | 26668319
|
出版者 | Elsevier
|
巻 | 5
|
開始ページ | 100091
|
発行日 | 2022-01-29
|
権利情報 | This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
薬学系
|