Background: This study prospectively assessed the diagnostic capacity of dynamic carbon-11 methionine (C-11 MET) positron-emission tomography (PET)/computed tomography for the diagnosis of pathologies in patients with primary unknown musculoskeletal lesions (MSLs). In total, 13 patients with MSLs underwent dynamic scans (5–10 [phase 1], 10–15 [phase 2], 15–20 [phase 3], 20–25 [phase 4], 25–30 [phase 5], and 30–35 [phase 6] min post-injection of C-11 MET). We statistically compared the maximum standardised uptake values (SUVmax) and corresponding retention index for dynamic scans (RI-SUV) for five benign MSLs (BMSLs), five primary malignant musculoskeletal tumours (PMMSTs), four metastatic musculoskeletal tumours (MMSTs), and three malignant lymphoma (ML) cases and explored their diagnostic capacities using receiver operating characteristic (ROC) curve analyses.
Results: SUVmax gradually decreased or remained similar with minimal fluctuations in all BMSL cases and four of five PMMST cases. In contrast, SUVmax increased over time in one case of PMMST and in all cases of MMST and ML. Significant differences were observed in SUVmax for all time phases and RI-SUV between BMSLs and MMSLs, in SUVmax for all time phases between PMMSTs and BMSLs, in SUVmax for all time phases and RI-SUV between non-PMMST-malignant tumours and BMSL, and in RI-SUV between non-PMMST-malignant tumours and PMMST. In ROC analyses, the areas under the curve yielded the highest values at 1.00 for differentiating most intergroup comparisons.
Conclusions: Dynamic C-11 MET PET scans have the potential to be good predictors of discriminating MSLs in patients with primary unknown MSLs in clinical practice.
掲載誌名
European Journal of Hybrid Imaging
ISSN
25103636
出版者
BioMed Central|Springer Nature
4
開始ページ
15
発行日
2020-08-26
権利情報
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
EDB ID
出版社版DOI
出版社版URL
フルテキストファイル
言語
eng
著者版フラグ
出版社版
部局
病院
医学系