直近一年間の累計
アクセス数 : ?
ダウンロード数 : ?
ID 110788
著者
タダツ, ヨウコ Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
六車, 直樹 Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
伊東, 進 Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School 徳島大学 教育研究者総覧
タダツ, マサヤ Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
クサカ, ヨシヒロ Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
岡本, 耕一 Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
イモト, ヨシタカ Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
タウエ, ヒロミ Faculty of Pharmaceutical Sciences, Institute of Health Biosciences, The University of Tokushima Graduate School
佐野, 茂樹 Faculty of Pharmaceutical Sciences, Institute of Health Biosciences, The University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
長尾, 善光 Faculty of Pharmaceutical Sciences, Institute of Health Biosciences, The University of Tokushima Graduate School 徳島大学 教育研究者総覧 KAKEN研究者をさがす
キーワード
immunofluorescence
infrared fluorescence
labeled antibody
資料タイプ
学術雑誌論文
抄録
Purpose: In recent years, labeled antibodies have been used for diagnostic imaging in many studies. In this study, we investigated the mode of binding in antibodies labeled with ICG derivatives newly developed for the diagnosis of microcarcinomas, and evaluated the optimal binding molar ratio between the labeling compounds and antibody. Methods: MUC1 antibody and ICG derivatives (ICG-ATT and ICG-sulfo-OSu) were used. ICG derivatives noncovalently bound to the antibody were removed with ethyl acetate, and the ratio of ICG derivatives covalently bound to the labeled antibody was confirmed. During purification of the labeled antibody, the amount of each labeling compound reacting with 1molecule of the antibody varied as follows: 4, 8, 16, and 32molar equivalents. Subsequently, the intensity of fluorescence was evaluated by spectroscopy and infrared fluoroscopy. Results : The ratio of residual ICG derivative labeling the antibody was 67.4% for ICG-ATT and 65.0% for ICG-sulfo-OSu. When fluorescent antibody labeled with ICG-ATT at anF/Pratio of 2.94or 4.18wasused, specific and clear fluorescent images of the antigen were obtained. When ICG-ATT-labeled antibody at an F/P ratio of 6.50 or 6.75 was used, the fluorescence intensity decreased and the fluorescent images of antigen became unclear. Conclusions: It was found that the ICG-ATT-labeled antibody was a more specific and sensitive marker than ICG-sulfo-OSu-labeled antibody, and that lower binding molar ratios of ICG-ATT were more useful for labeling the antibody.
掲載誌名
The journal of medical investigation : JMI
ISSN
13431420
cat書誌ID
AA11166929
53
1-2
開始ページ
52
終了ページ
60
並び順
52
発行日
2006-02
EDB ID
出版社版DOI
出版社版URL
フルテキストファイル
言語
eng
著者版フラグ
出版社版
部局
医学系
病院
薬学系