ID | 110788 |
著者 |
タダツ, ヨウコ
Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
六車, 直樹
Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
伊東, 進
Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
徳島大学 教育研究者総覧
タダツ, マサヤ
Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
クサカ, ヨシヒロ
Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
岡本, 耕一
Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
イモト, ヨシタカ
Department of Digestive and Cardiovascular Medicine, Institute of Health Biosciences, The University of Tokushima Graduate School
タウエ, ヒロミ
Faculty of Pharmaceutical Sciences, Institute of Health Biosciences, The University of Tokushima Graduate School
佐野, 茂樹
Faculty of Pharmaceutical Sciences, Institute of Health Biosciences, The University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
長尾, 善光
Faculty of Pharmaceutical Sciences, Institute of Health Biosciences, The University of Tokushima Graduate School
徳島大学 教育研究者総覧
KAKEN研究者をさがす
|
キーワード | immunofluorescence
infrared fluorescence
labeled antibody
|
資料タイプ |
学術雑誌論文
|
抄録 | Purpose: In recent years, labeled antibodies have been used for diagnostic imaging in many studies. In this study, we investigated the mode of binding in antibodies labeled with ICG derivatives newly developed for the diagnosis of microcarcinomas, and evaluated the optimal binding molar ratio between the labeling compounds and antibody. Methods: MUC1 antibody and ICG derivatives (ICG-ATT and ICG-sulfo-OSu) were used. ICG derivatives noncovalently bound to the antibody were removed with ethyl acetate, and the ratio of ICG derivatives covalently bound to the labeled antibody was confirmed. During purification of the labeled antibody, the amount of each labeling compound reacting with 1molecule of the antibody varied as follows: 4, 8, 16, and 32molar equivalents. Subsequently, the intensity of fluorescence was evaluated by spectroscopy and infrared fluoroscopy. Results : The ratio of residual ICG derivative labeling the antibody was 67.4% for ICG-ATT and 65.0% for ICG-sulfo-OSu. When fluorescent antibody labeled with ICG-ATT at anF/Pratio of 2.94or 4.18wasused, specific and clear fluorescent images of the antigen were obtained. When ICG-ATT-labeled antibody at an F/P ratio of 6.50 or 6.75 was used, the fluorescence intensity decreased and the fluorescent images of antigen became unclear. Conclusions: It was found that the ICG-ATT-labeled antibody was a more specific and sensitive marker than ICG-sulfo-OSu-labeled antibody, and that lower binding molar ratios of ICG-ATT were more useful for labeling the antibody.
|
掲載誌名 |
The journal of medical investigation : JMI
|
ISSN | 13431420
|
cat書誌ID | AA11166929
|
巻 | 53
|
号 | 1-2
|
開始ページ | 52
|
終了ページ | 60
|
並び順 | 52
|
発行日 | 2006-02
|
EDB ID | |
出版社版DOI | |
出版社版URL | |
フルテキストファイル | |
言語 |
eng
|
著者版フラグ |
出版社版
|
部局 |
医学系
病院
薬学系
|